Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
Chinese journal of integrative medicine ; (12): 257-262, 2022.
Article in English | WPRIM | ID: wpr-928944

ABSTRACT

OBJECTIVE@#To explore if acupoint injection can improve analgesic effects or delivery outcomes in parturients who received combined spinal-epidural analgesia (CSEA) and patient-controlled epidural analgesia (PCEA) for labor analgesia.@*METHODS@#A total of 307 participants were prospectively collected from July 2017 to December 2019. The participants were randomized into the combined acupoint injection with CSEA plus PCEA group (AICP group, n=168) and CSEA plus PCEA group (CP group, n=139) for labor analgesia using a random number table. Both groups received CSEA plus PCEA at cervical dilation 3 cm during labor process, and parturients of the AICP group were implemented acupoint injection for which bilateral acupoint of Zusanli (ST 36) and Sanyinjiao (SP 6) were selected in addition. The primary outcome was Visual Analogue Scale (VAS) score, and the secondary outcomes were obstetric outcomes and requirement of anesthetics doses. Safety evaluations were performed after intervention.@*RESULTS@#The VAS scores were significantly lower in the AICP group than in the CP group at 10, 30, 60, and 120 min after labor analgesia (all P<0.05). The latent phase of the AICP group was shorter than that of the CP group (P<0.05). There were less additional anesthetics consumption, lower incidences of uterine atony, fever, pruritus and urinary retention in the AICP group than those in the CP group (all P<0.05).@*CONCLUSION@#Acupoint injection combined CSEA plus PCEA for labor analgesia can decrease the anesthetic consumption, improve analgesic quality, and reduce adverse reactions in the parturients. (Registration No. ChiMCTR-2000003120).


Subject(s)
Female , Humans , Pregnancy , Acupuncture Points , Analgesia, Obstetrical/adverse effects , Analgesia, Patient-Controlled/adverse effects , Anesthetics/pharmacology , Labor, Obstetric
3.
Rev. bras. enferm ; 73(2): e20180757, 2020. tab
Article in English | LILACS, BDENF | ID: biblio-1098807

ABSTRACT

ABSTRACT Objetives: To investigate the association between analgesia during labor and occurrence of neonatal outcomes. Methods: Retrospective cohort study with medical records of 850 parturient. The exposure variable of interest was receiving pharmacological analgesia during labor and neonatal outcomes were: one- and five-minute Apgar, resuscitation maneuvers and referral of the newborn to Neonatal ICU. A logistic regression was carried out to obtain Odds Ratios and 95% confidence interval, with adjustment for confounding factors. Results: Among the women studied, 35% received analgesia and this use was associated with a greater chance of neonatal outcomes such as one-minute Apgar < 7 (p <0.0001), resuscitation maneuvers (p <0.001) and referral to the Neonatal ICU (p = 0.004), mostly were among low-risk pregnant women, even after adjustments. Conclusions: The use of pharmacological analgesia during labor is associated with one-minute Apgar < 7, resuscitation maneuvers and referral to the Neonatal ICU.


RESUMEN Objetivos: Investigar la asociación entre la analgesia en el trabajo de parto y la aparición de resultados neonatales. Métodos: Estudio de cohorte retrospectivo con datos de 850 parturientas. La exposición fue recibir analgesia farmacológica en el trabajo de parto, resultados: Apgar del primer y quinto minuto < 7, maniobras de reanimación y derivación a la UCIN. La regresión logística se utilizó para obtener el Odds Ratio (OR) y el intervalo de confianza del 95% (IC95%), ajustado por variables de confusión. Resultados: De las mujeres estudiadas, el 35% recibió analgesia y su uso se asoció con una mayor probabilidad de resultados como: Apgar en el primer minuto < 7 (p<0,0001), maniobras de reanimación (p<0,001) y derivación a la UCIN (p=0,004). Conclusiones: el uso de analgesia farmacológica durante el trabajo de parto se asoció con Apgar < 7 en el primer minuto, maniobras de reanimación y derivación a la UCIN.


RESUMO Objetivos: Investigar a associação entre analgesia no trabalho de parto e ocorrência de desfechos neonatais. Métodos: Estudo de coorte retrospectiva com dados de prontuários de 850 parturientes. A exposição foi receber analgesia farmacológica no trabalho de parto e os desfechos: Apgar do primeiro e quinto minuto < 7, manobras de reanimação e encaminhamento para Unidade de Terapia Intensiva Neonatal (UTI). Utilizou-se regressão logística para obter Odds Ratio (OR) e intervalo de 95% de confiança (IC95%), sendo ajustados por confundidores. Resultados: Das mulheres estudadas, 35% receberam analgesia e seu uso esteve associado a maior chance de desfechos, como: Apgar do primeiro minuto < 7 (p<0,0001), manobras de reanimação (p<0,001) e encaminhamento para UTI Neonatal (p=0,004), principalmente entre gestantes de risco habitual, mesmo após ajustes. Conclusões: O uso de analgesia farmacológica durante o trabalho de parto foi associado a Apgar do primeiro minuto < 7, manobras de reanimação e encaminhamento para UTI neonatal.


Subject(s)
Adolescent , Adult , Female , Humans , Infant, Newborn , Pregnancy , Labor, Obstetric/drug effects , Analgesia, Obstetrical/adverse effects , Analgesia, Obstetrical/statistics & numerical data , Apgar Score , Pregnancy Complications/epidemiology , Brazil/epidemiology , Pregnancy Outcome/epidemiology , Retrospective Studies , Risk Factors , Cohort Studies , Analgesia, Obstetrical/methods
4.
Rev. chil. anest ; 49(2): e20180757, 2020. tab
Article in English | LILACS | ID: biblio-1092565

ABSTRACT

ABSTRACT Objetives: To investigate the association between analgesia during labor and occurrence of neonatal outcomes. Methods: Retrospective cohort study with medical records of 850 parturient. The exposure variable of interest was receiving pharmacological analgesia during labor and neonatal outcomes were: one- and five-minute Apgar, resuscitation maneuvers and referral of the newborn to Neonatal ICU. A logistic regression was carried out to obtain Odds Ratios and 95% confidence interval, with adjustment for confounding factors. Results: Among the women studied, 35% received analgesia and this use was associated with a greater chance of neonatal outcomes such as one-minute Apgar < 7 (p <0.0001), resuscitation maneuvers (p <0.001) and referral to the Neonatal ICU (p = 0.004), mostly were among low-risk pregnant women, even after adjustments. Conclusions: The use of pharmacological analgesia during labor is associated with one-minute Apgar < 7, resuscitation maneuvers and referral to the Neonatal ICU.


RESUMEN Objetivos: Investigar la asociación entre la analgesia en el trabajo de parto y la aparición de resultados neonatales. Métodos: Estudio de cohorte retrospectivo con datos de 850 parturientas. La exposición fue recibir analgesia farmacológica en el trabajo de parto, resultados: Apgar del primer y quinto minuto < 7, maniobras de reanimación y derivación a la UCIN. La regresión logística se utilizó para obtener el Odds Ratio (OR) y el intervalo de confianza del 95% (IC95%), ajustado por variables de confusión. Resultados: De las mujeres estudiadas, el 35% recibió analgesia y su uso se asoció con una mayor probabilidad de resultados como: Apgar en el primer minuto < 7 (p<0,0001), maniobras de reanimación (p<0,001) y derivación a la UCIN (p=0,004). Conclusiones: el uso de analgesia farmacológica durante el trabajo de parto se asoció con Apgar < 7 en el primer minuto, maniobras de reanimación y derivación a la UCIN.


RESUMO Objetivos: Investigar a associação entre analgesia no trabalho de parto e ocorrência de desfechos neonatais. Métodos: Estudo de coorte retrospectiva com dados de prontuários de 850 parturientes. A exposição foi receber analgesia farmacológica no trabalho de parto e os desfechos: Apgar do primeiro e quinto minuto < 7, manobras de reanimação e encaminhamento para Unidade de Terapia Intensiva Neonatal (UTI). Utilizou-se regressão logística para obter Odds Ratio (OR) e intervalo de 95% de confiança (IC95%), sendo ajustados por confundidores. Resultados: Das mulheres estudadas, 35% receberam analgesia e seu uso esteve associado a maior chance de desfechos, como: Apgar do primeiro minuto < 7 (p<0,0001), manobras de reanimação (p<0,001) e encaminhamento para UTI Neonatal (p=0,004), principalmente entre gestantes de risco habitual, mesmo após ajustes. Conclusões: O uso de analgesia farmacológica durante o trabalho de parto foi associado a Apgar do primeiro minuto < 7, manobras de reanimação e encaminhamento para UTI neonatal.


Subject(s)
Humans , Female , Pregnancy , Infant, Newborn , Adolescent , Adult , Labor, Obstetric/drug effects , Analgesia, Obstetrical/adverse effects , Apgar Score , Pregnancy Outcome/epidemiology , Chi-Square Distribution , Logistic Models , Odds Ratio , Retrospective Studies , Risk Factors , Cohort Studies , Analgesia, Obstetrical/methods
5.
Rev. bras. anestesiol ; 69(1): 7-12, Jan.-Feb. 2019. tab
Article in English | LILACS | ID: biblio-977416

ABSTRACT

Abstract Introduction: Lumbar epidural block is an effective and routinely used technique for labor pain relief, and the combined spinal-epidural block has the benefit of using lower doses of local anesthetics and rapid onset of analgesia. The objective of this study was to evaluate the effectiveness and safety of two anesthetic techniques: combined spinal-epidural block and continuous epidural block in pregnant women for labor analgesia. Methods: Eighty patients, ASA II and III, with cephalic presentation and cervical dilation between 5 and 6 cm, undergoing labor analgesia, allocated in two groups according to the anesthetic technique: combined spinal-epidural (GI) and continuous epidural (GII). Pain severity before the blockade, time to complete analgesia, degree of motor blockade, time to full cervical dilation, duration of the second stage of labor, pain severity during the 1st and 2nd stage of labor, type of delivery, use of oxytocin during labor, maternal cardiocirculatory and respiratory parameters and adverse events, and neonatal repercussions were recorded. Results: At the time of anesthesia, pain severity was similar in both groups. Pain relief was faster in GI (4.5 ± 1.5 min) when compared to GII (11.6 ± 4.6 min) p = 0.01; pain scores in the first and second stages of delivery were lower in GI (0.9 ± 0.3 and 1.8 ± 0.7, respectively) when compared to GII (1.9 ± 0.6 and 2.2 ± 0.5, respectively), with p = 0.01 only in the first stage of labor; there was need for local anesthetics supplementation in GII; there were more frequent spontaneous deliveries in GI (80% of patients) than in GII (50%) (p = 0.045) and more frequent use of instrumental (p = 0.03) in GII (12 patients) compared to GI (4 patients); the frequency of cesarean deliveries was significantly higher (p = 0.02) in Group II than in Group I, with 4 cases in GI and 8 cases in GII; absence of maternal cardiocirculatory and respiratory changes and neonatal repercussions; more frequent pruritus in GI (10 patients) and (0 patients in GII) (p = 0.02). Conclusion: The combined blockade proved to be effective with better quality of analgesia and greater comfort for pregnant women, constituting a good option for the practice of obstetric analgesia.


Resumo Introdução: O bloqueio peridural lombar constitui técnica eficaz e rotineiramente empregada para alívio da dor do parto e o bloqueio combinado raquiperidural tem como benefícios o emprego de doses menores de anestésicos locais e rápido início de analgesia. O objetivo do estudo foi avaliar comparativamente a eficácia e a segurança de duas técnicas anestésicas: bloqueio combinado raquiperidural e peridural contínua em grávidas submetidas à analgesia de parto. Método: Oitenta gestantes, ASA 2 e 3, apresentação cefálica e dilatação cervical entre cinco e seis centímetros, submetidas à analgesia de parto, distribuídas em dois grupos de acordo com a técnica anestésica: técnica combinada raquiperidural (GI) e peridural contínua (GII). Avaliaram-se: intensidade de dor antes do bloqueio; tempo para completa analgesia; grau do bloqueio motor; tempo para dilatação cervical total; duração do 2° estágio do trabalho de parto; intensidade de dor durante o 1° e o 2° estágio do trabalho de parto; tipo de parto; uso de ocitocina durante trabalho de parto; parâmetros cardiocirculatórios, respiratórios e eventos adversos maternos; repercussões neonatais. Resultados: No momento da anestesia a intensidade de dor era semelhante em ambos os grupos. O alívio da dor foi mais rápido no GI (4,5 ± 1,5 min) quando comparado com o GII (11,6 ± 4,6 min) p = 0,01; os escores de dor no primeiro e segundo estágios de parto foram menores no GI (0,9 ± 0,3) e (1,8 ± 0,7) quando comparados com o GII (1,9 ± 0,6) e (2,2 ± 0,5) com p = 0,01 somente no primeiro estágio de trabalho de parto; houve necessidade de complementação com anestésicos locais no GII; partos espontâneos mais frequentes em GI (80% das pacientes) do que em GII (50%) p = 0,045 e instrumentais mais frequentes (p = 0,03) em GII (12 pacientes) quando comparadas com o GI (quatro pacientes); a frequência de partos cesáreos foi significativamente maior (p = 0,02) no Grupo II do que no Grupo I, quatro casos no GI e oito no GII; ausência de alterações cardiocirculatórias e respiratórias maternas e repercussões neonatais; prurido mais frequente no GI (10 pacientes) e (0 paciente no GII) p = 0,02. Conclusão: O bloqueio combinado mostrou-se eficaz com melhor qualidade de analgesia e maior conforto às gestantes, constitui boa opção para a prática de analgesia obstétrica.


Subject(s)
Humans , Female , Pregnancy , Young Adult , Analgesia, Epidural/adverse effects , Analgesia, Obstetrical/methods , Double-Blind Method , Analgesia, Obstetrical/adverse effects , Treatment Outcome , Combined Modality Therapy , Anesthesia, Spinal/adverse effects , Nerve Block/adverse effects , Nerve Block/methods
6.
Guatemala; IGSS; 2017. 100 p. ilus.(Guías de práctica clínica basadas en evidencia, 54).
Monography in Spanish | LILACS, IGSSMED, LIGCSA | ID: biblio-1361630

ABSTRACT

Esta guía contiene definiciones y etapas del trabajo de parto, aunque no hay un patrón estándar. El trabajo puede dividirse en tres estadios, 1ro trabajo de parto dilataciòn, 2do dilataciòn cervical completa, 3ro nacimiento neonato. la analgesia epidural sus ventajas, alivio completo, menor riesgo, menos riesgo depresión en el feto, menor riesgo depresión de las fuerzas del parto. Indicaciones medicas; Pre eclampsia, afecciones cardiacas, afeciones respiratorias, enfermedades neurológicas crónicas, epilepsia. Contraindicaciones; Rechazo por la paciente, control inadecuado del feto, terapia anticougulante. espina bifida.


Subject(s)
Humans , Female , Pregnancy , Infant, Newborn , Labor, Obstetric , Analgesia, Epidural/adverse effects , Analgesia, Epidural/methods , Analgesia, Obstetrical/adverse effects , Injections, Epidural/methods , Bupivacaine/pharmacology , Labor Pain/drug therapy , Dilatation/classification , Anesthetics, Local/administration & dosage
7.
Rev. bras. anestesiol ; 65(4): 306-309, July-Aug. 2015. ilus
Article in English | LILACS | ID: lil-755139

ABSTRACT

We report the case of a 25-year-old woman, who received epidural analgesia for labor pain and subsequently presented post-dural puncture headache. Conservative treatment was applied and epidural blood patch was performed. In the absence of clinical improvement and due to changes in the postural component of the headache, a brain imaging test was performed showing a bilateral subdural hematoma. The post-dural puncture headache is relatively common, but the lack of response to established medical treatment as well as the change in its characteristics and the presence of neurological deficit, should raise the suspicion of a subdural hematoma, which although is rare, can be lethal if not diagnosed and treated at the right time.

.

Apresentamos o caso clínico de uma paciente de 25 anos na qual uma técnica peridural foi aplicada durante o trabalho de parto e posteriormente apresentou cefaleia com características de cefaleia pós-punção dural. Foi iniciado tratamento conservador e tampão de sangue peridural. Devido à ausência de melhoria clínica e à mudança do componente postural da cefaleia, decidiu-se fazer um exame de imagem cerebral que demonstrou a presença de hematoma subdural bilateral. A cefaleia pós-punção dural é relativamente frequente, mas a falta de resposta ao tratamento médico instaurado, assim como a mudança em suas características e a presença de foco neurológico, deve levantar a suspeita de presença de um hematoma subdural que, embora infrequente, pode chegar a ser devastador se não for diagnosticado e tratado oportunamente.

.

Presentamos el caso clínico de una paciente de 25 años de edad, a quien se le realizó una técnica epidural durante el trabajo de parto y posteriormente presentó cefalea con características de cefalea pospunción dural. Se inició tratamiento conservador y se realizó parche hemático epidural. Ante la falta de mejoría clínica y debido al cambio en el componente postural de la cefalea, se decidió realizar una prueba de imagen cerebral que demostró la presencia de hematoma subdural bilateral. La cefalea pospunción dural es relativamente frecuente, pero la falta de respuesta al tratamiento médico instaurado, así como el cambio en sus características y la presencia de focalidad neurológica, deben hacer sospechar la presencia de un hematoma subdural que, aunque infrecuente, puede llegar a ser devastador si no se diagnostica y trata oportunamente.

.


Subject(s)
Humans , Female , Pregnancy , Adult , Analgesia, Epidural/adverse effects , Analgesia, Obstetrical/adverse effects , Hematoma, Subdural/etiology , Analgesia, Epidural/methods , Analgesia, Obstetrical/methods , Blood Patch, Epidural/methods , Labor Pain/drug therapy , Post-Dural Puncture Headache/etiology , Post-Dural Puncture Headache/therapy , Neuroimaging/methods , Hematoma, Subdural/diagnosis
8.
Anest. analg. reanim ; 27(2): 5-5, dic. 2014.
Article in Spanish | LILACS | ID: lil-754116

ABSTRACT

Para todas las mujeres el trabajo de parto y el parto son experiencias dolorosas, sumado a esto, el miedo y la ansiedad pueden incrementarlo y dificultar su manejo. Así mismo el dolor durante la labor de parto es equiparable con el dolor post-quirúrgico, sin olvidarnos que además la atención del trabajo de parto es un procedimiento médico de alto valor y prevalencia a nivel mundial. En la analgesia obstétrica el estándar de oro es la técnica regional pero cuando esta se encuentra contraindicada o rechazada por la paciente, habitualmente se decide abandonar la analgesia y proseguir la labor de parto con dolor; dejando a un lado toda la información descrita en la literatura con respecto a que el adecuado tratamiento del dolor disminuye la morbilidad y mortalidad materno fetal, además de obtenerse mejorías en relación al costo-beneficio acortando el tiempo de estancia hospitalaria e impactando favorablemente en la economía de los pacientes. El uso de sedantes y narcóticos en la paciente en labor de parto siempre ha sido motivo de controversia ya que estos medicamentos tienden a cruzar la membrana placentaria y pueden tener efectos nocivos sobre el neonato. Sin embargo; los medicamentos más nuevos como remifentanilo debido a sus propiedades farmacocinéticas aunque cruzan la placenta no producen efectos secundarios clínicamente significativos en el binomio madre-feto. Además de que la dexmedetomidina no pasa a la circulación fetal, una razón de valor por la cual puede ser usada en conjunto con remifentanilo para la analgesia en labor de parto y obtener de esta manera un mejor control del dolor, estancia más confortable y hemodinámia estable aún en las pacientes obstétricas en estado crítico; ya que es de carácter imperativo ofrecer la mejor atención y cuidados posibles tanto a la madre como al neonato.


For all women in labor and childbirth are painful experiences, in addition to that, fear and anxiety can increase it and hinder its management. Also pain during labor is equated with pain after surgery, without forgetting also the attention of labor is a medical procedure of high value and prevalence worldwide. In obstetric analgesia the gold standard is the regional technique but when this is contraindicated or refused by the patient, usually you decide to leave analgesia and further labor pain, although there is enough information that the proper approach to pain decreases maternal-fetal morbidity and mortality, in addition to improvements obtained in a cost-effective shortening the length of hospital stay and impacting positively on patients economy. The use of sedatives and narcotics in the patient in labor has always been controversial as these drugs tend to cross the uteroplacental barrier and can have adverse effects on the neonate. But the newer drugs such as remifentanil and dexmedetomidine because of their pharmacokinetic properties do not cross the placenta so significantly further literature refers that dexmedetomidine does not pass into the fetal circulation. One more reason to value which can be used in conjunction remifentanil for analgesia in labor and thereby obtain better pain management, better state of comfort, and hemodynamics in obstetric patients and that it is mandatory to provide the best possible care and attention to both the mother and the neonate.


Subject(s)
Humans , Analgesia, Obstetrical/adverse effects , Dexmedetomidine/therapeutic use , Dexmedetomidine/chemistry , Analgesics, Opioid/administration & dosage , Analgesics, Opioid/adverse effects , Analgesics, Opioid/pharmacokinetics , Labor Pain
9.
Rev. Assoc. Med. Bras. (1992) ; 55(4): 405-409, 2009. tab
Article in English | LILACS | ID: lil-525044

ABSTRACT

OBJECTIVE: Epidural (EA) and combined spinal-epidural (CSE) techniques have both been utilized for labor analgesia. This study compared the effects on the mother and newborn of these techniques in labor analgesia and anesthesia. METHODS: Forty pregnant women received epidural analgesia with 15 mL of 0.125 percent ropivacaine (EA group) and 5 µg of sufentanil plus 2.5mg bupivacaine in the subarachnoid space (CSE group). Pain intensity, sensory blockade level, latency time, motor block intensity, labor analgesia duration, epidural analgesia duration, maternal hypotension, and pruritus were evaluated. The newborns were evaluated by Apgar and the neurological and adaptive capacity score (NACS) developed by Amiel-Tison. RESULTS: There were no significant statistical differences between groups for pain scores, latency time, sensory blockade level, and Apgar score. Motor block, labor analgesia duration, and epidural analgesia duration were greater in the CSE group, whose seven mothers had mild pruritus. The NACS were greater in the EA group after half, two, and 24 hours. Ninety five percent of EA group newborns and 60 percent of CSE group newborns were found to be neurologically healthy at the 24 hour examination. CONCLUSION: EA and CSE analgesia relieved maternal pain during obstetric analgesia, but CSE mothers had pruritus and a longer labor. Newborns of mothers who received epidural analgesia showed the best NACS.


OBJETIVO: A peridural (AP) e a técnica de duplo bloqueio (DB) são utilizadas em analgesia para o trabalho de parto. Este estudo comparou os efeitos na mãe e no feto de ambas as técnicas em analgesia e anestesia para o parto. MÉTODOS: Quarenta parturientes ASA I e II receberam por via peridural 15 ml de ropivacaína a 0,125 por cento (grupo AP) e 5 µg de sufentanil com 2,5 mg bupivacaína por via subaracnóidea (grupo DB). Foram avaliados: intensidade de dor, altura do bloqueio sensitivo, tempo de latência, bloqueio motor, duração da analgesia de parto, tempo para a resolução do parto, hipotensão materna e presença de prurido. Os recém-nascidos foram avaliados pelo índice de Apgar e escore da capacidade adaptativa e neurológica (ECAN), método de Amiel-Tison. RESULTADOS: Não houve diferenças significativas entre os grupos na intensidade da dor, no tempo de latência, no nível do bloqueio sensitivo e no índice de Apgar. O bloqueio motor, a duração da analgesia e o tempo para resolução do parto foram maiores no grupo DB, do qual sete parturientes apresentaram prurido leve. ECAN foi maior no grupo AP após meia hora, duas horas e 24 horas. Noventa e cinco por cento dos recém-nascidos do grupo AP e 60 por cento do grupo DB foram considerados neurologicamente vigorosos ao exame de 24 horas. CONCLUSÃO: As duas técnicas mostraram-se eficazes para analgesia do trabalho de parto. As parturientes do grupo DB apresentaram prurido e trabalho de parto mais prolongado. Recém-nascidos de mães que receberam analgesia de parto via peridural apresentaram melhor ECAN.


Subject(s)
Female , Humans , Infant, Newborn , Pregnancy , Young Adult , Analgesia, Epidural/methods , Analgesia, Obstetrical/methods , Anesthesia, Conduction/methods , Fetus/drug effects , Labor, Obstetric/drug effects , Amides , Anesthetics , Analgesia, Epidural/adverse effects , Analgesia, Obstetrical/adverse effects , Anesthesia, Conduction/adverse effects , Chi-Square Distribution , Labor Pain/physiopathology , Mothers , Pruritus/chemically induced , Sufentanil , Young Adult
10.
Rev. colomb. anestesiol ; 35(1): 29-35, ene.-mar. 2007. ilus
Article in Spanish | LILACS | ID: lil-490991

ABSTRACT

Evaluar la eficacia de aplicar fentanyl más midazolam en reducir la incidencia de náusea y vómito secundarios a la limpieza de la cavidad peritoneal en pacientes sometidas a cesárea bajo anestesia subaracnoidea. Se analizaron los resultados por medio de regresión binomial. Métodos: Ensayo clínico controlado triple enmascarado entre pacientes llevadas a cesárea bajo anestesia raquídea. A 163 pacientes se les administró por vía endovenosa 50 mcg de fentanyl más 1 mg de midazolam, mientras que a 164 solución salina como placebo al momento de terminar la histerorrafia. Resultados: La aplicación de fentanyl más midazolam reduce en 8.45 (IC95 3.07-23.27) veces la probabilidad de presentar náusea. Diferencias que se mantienen aún luego de ajustar por las otras posibles explicaciones al fenómeno (7.99, IC95 2.91-21.92). La luxación del útero implica también un riesgo para náusea de 2.33 (IC95 1.29-4.22) veces. También se encontró reducción significativa en la incidencia de vómito, dolor y disnea, sin incremento en la frecuencia de prurito, temblor, malestar e hipoxemia. Conclusiones: La administración simultánea de 50 mcg de fentanyl más 1 mg de midazolam por vía endovenosa al momento de terminar la histerorrafia, reduce la incidencia de náusea y vómito secundaria a la manipulación del peritoneo al limpiar la cavidad abdominal, sin incremento de los efectos secundarios.


Subject(s)
Female , Anesthesia, Conduction , Analgesia, Obstetrical/adverse effects , Cesarean Section , Fentanyl/analogs & derivatives , Fentanyl/therapeutic use , Midazolam/therapeutic use , Postoperative Nausea and Vomiting/therapy
11.
Cuad. Hosp. Clín ; 50(1): 55-61, 2005. tab
Article in Spanish | LILACS, LIBOCS | ID: lil-428518

ABSTRACT

OBJETIVO: la administración de levobupivacaina en el espacio epidural para analgesia del trabajo de parto, en concentración de 0.185% es capaz de producir un efectivo control del dolor del trabajo de parto, sin bloqueo motor, ni efectos sistémicos y fetales indeseables. PACIENTES Y MÉTODOS: el estudio se realizó en las pacientes internadas en la sala de pre-partos del Hospital de La Mujer. Se tomó como muestra un total de 30 pacientes, divididas en dos grupos de estudio Grupo A (n = 15), a las cuales se administrará L-bupivacaina al 0.185% con adición de fentanyl, y un Grupo B (n = 15), al cual se administró bupivacaina al 0.125% más fentanyl. RESULTADOS: la calidad de la analgesia de 0 en todas las pacientes, manteniéndose en este nivel durante todo el trabajo de parto en el 80% de los casos. Ninguna paciente presentó bloqueo motor, ni efectos sistémicos indeseables producidos por la levobupivacaina. En ningún caso las calificaciones de Apgar fueron bajas. La frecuencia cardiaca fetal no presentó alteraciones (p<0.5). La actividad uterina se vio significativamente afectada en el grupo B (p < 0.06). El empleo de oxitocicos en el grupo B fue significativamente mayor (p<0.003). El bloqueo motor fue significativamente menor en el grupo A (p < 0.07).


OBJECTIVES: the administration of l-bupivacaine into the epidural space for getting an obstetric analgesia for labour at 0.185% concentration doesn't has systemic or foetal adverse effects. PATIENTS AND METHODS: the study has been done at the Hospital de la Mujer; on the patients interned to the labour room. A group of 30 women in active labour was divided in two study groups Group A (n=15) who ABSTRACT: received L-bupivacaine 0.185% plus fentanyl, Group B (n=15) who received bupivacaine 0.125% plus fentanyl. RESULTS: we found a quality of analgesia of 0 in all of the patients, maintaining this level during all of the labour time in 80% of the patient. Niether one presented motor blockage, adverse effects produced by the L-bupivacaine. In any case we have seen low Apgar scores. The foetus cardiac frequency has not been affected (p<0.5). The uterine activity has been affected in the B group (p<0.006). The use of oxytocin has been greater in the B group (p<0.003). The motor blockage has been minor in the A group (p<0.07)


Subject(s)
Humans , Female , Labor, Obstetric , Analgesia , Anesthesia and Analgesia , Analgesia, Obstetrical/classification , Analgesia, Obstetrical/adverse effects , Analgesia, Obstetrical/mortality , Analgesia, Obstetrical/methods , Heart Rate , Heart Rate/radiation effects , Heart Rate/immunology
12.
Rev. bras. anestesiol ; 51(4): 325-30, jul.-ago. 2001. ilus
Article in Portuguese, English | LILACS | ID: lil-297986

ABSTRACT

Justificativa e Objetivos: O bloqueio peridural constitui técnica utilizada para alívio da dor durante o trabalho de parto. Apesar das vantagens, näo é isenta de complicaçöes, como, por exemplo, o pneumoencéfalo iatrogênico, diagnosticado após bloqueio peridural, com punçäo acidental de duramáter. Relato de caso: Paciente de 16 anos, estado físico ASA I, sem antecedentes anestésicos, submetida a bloqueio peridural contínuo para analgesia de parto. Após várias tentativas de punçöes no espaço L3-L4, ocorreu punçäo acidental de duramáter. Optou-se por nova punçäo em L3-L4, e após identificaçäo do espaço peridural empregando-se a técnica da perda da resistência com ar, injetou-se o anestésico local e fentanil, seguido de passagem do cateter. Após 20 minutos da instalaçäo do bloqueio, ocorreu sofrimento fetal, com indicaçäo de cesariana, sendo administrada dose complementar de anestésico local pelo cateter. A paciente permaneceu hemodinamicamente estável e consciente durante a cirurgia, com lenta recuperaçäo do bloqueio motor (14 h). No pós-operatório, apresentou dois episódios de crise convulsiva, com intervalo de 12 horas entre eles, que reverteram espontaneamente. A avaliaçäo neurológica era normal e a tomografia computadorizada revelou imagem com densidade de ar compatível com pneumoencéfalo. A paciente teve alta três dias após, sem seqüelas. Conclusöes: O caso confirma a possibilidade de se causar pneumoencéfalo iatrogênico durante a realizaçäo de bloqueio peridural, empregando-se a técnica da perda de resistência ao ar para a identificaçäo do espaço peridural. Na presença de sinais e sintomas de irritaçäo meníngea, a tomografia computaforizada é o meio diagnóstico recomendado para o diagóstico diferencial entre pneumoencéfalo e as demais causas


Subject(s)
Humans , Adolescent , Female , Pregnancy , Analgesia, Epidural/adverse effects , Dura Mater/injuries , Labor, Obstetric , Pneumocephalus/etiology , Analgesia, Obstetrical/adverse effects , Tomography, X-Ray Computed
13.
Rev. colomb. anestesiol ; 26(1): 17-24, ene.-mar. 1998. tab
Article in Spanish | LILACS | ID: lil-218041

ABSTRACT

A pesar de que los protocolos de analgesia continua con anestésicos locales y opioides han demostrado ser seguros, no se dispone de comprobaciones en nuestro medio, lo que ha limitado su difusión. Nuestro objetivo fue comparar la duración del segundo período del trabajo de parto, bienestar fetal y grado de satisfacción de la materna con dos técnicas de analgesia obstétrica en un estudio prospectivo de corte. Se realizó en sala de partos de institución de tercer nivel, con disponibilidad permanente de anestesiólogo, durante cuatro meses, con muestra de conveniencia de nulíparas a término con feto en posición cefálica. Resultados: Se estudiaron 102 pacientes, 77 con infusión y 25 con analgesia en bolos. Las características demográficas y clínicas fueron similares, excepto la dilatación al iniciar la analgesia. La proporción de cesáreas fue la misma en ambos grupos y la calidad de la analgesia en el primer período fue similar. No se encontró diferencia en el desenlace del parto, la duración o el bienestar fetal con ambas técnicas analgésicas. Conclusión: En nuestras pacientes es posible seguir las recomendaciones de analgesia continua que aparecen en la literatura, sin aumento de los riesgos y con igual beneficio. Recomendación: Es importante para un buen desenlace del trabajo de parto el uso de epidurales tempranas, estimulación de la contracción uterina con oxitocina y monitoreo continuo materno-fetal


Subject(s)
Humans , Female , Pregnancy , Analgesia, Obstetrical/methods , Analgesia, Epidural , Anesthesia, Local , Analgesia, Obstetrical/adverse effects , Analgesia, Obstetrical/trends , Analgesia, Epidural/trends , Anesthesia, Local/trends
14.
Rev. colomb. anestesiol ; 26(1): 33-44, ene.-mar. 1998. tab
Article in Spanish | LILACS | ID: lil-218043

ABSTRACT

Objetivos: comparar la efectividad y seguridad de la analgesia epidural con un anestésico local (bupivacaína) con adición de opioide (fentanil o tramadol) durante la fase activa del trabajo de parto. Diseño: experimento clínico controlado, aleatorizado y doble ciego. Pacientes: incluimos 64 mujeres ASA I y II, con embarazo a término, sin indicación quirúrgica ni contraindicación para analgesia regional. Intervenciones: analgesia peridural con 10 ml de: Grupo I Bupivacaína 0.25 por ciento mas fentanil 50 ig. Grupo 2 Bupivacaína 0,25 por ciento mas tramadol 50 mg. Mediciones: respuesta al dolor con escala visual análoga (EVA),latencia y duración de la analgesia, bienestar materno (FC, TA, FR) y fetal (FCF, Apgar), evolución del trabajo de parto, efectos colaterales importantes y complicaciones. Conclusiones: los resultados de este ensayo clínico confirman la seguridad y la utilidad de la analgesia peridural en obstetricia, usando un anestésico local mas opioide. El tramadol demostró ser una alternativa adecuada (quizá mejor que el fentanil) por su efectividad y ausencia de efectos adversos relevantes


Subject(s)
Humans , Female , Pregnancy , Analgesia, Obstetrical/adverse effects , Analgesia, Epidural/adverse effects , Analgesia, Obstetrical/methods , Analgesia, Obstetrical/trends , Analgesia, Epidural , Analgesia, Epidural/trends , Bupivacaine/adverse effects , Bupivacaine/administration & dosage , Fentanyl , Fentanyl/therapeutic use , Tramadol , Tramadol/adverse effects
16.
Proceedings. 1998; 12 (3-4): 74-7
in English | IMEMR | ID: emr-49383
18.
Rev. colomb. obstet. ginecol ; 47(1): 29-32, ene.-mar. 1996.
Article in Spanish | LILACS | ID: lil-293069

ABSTRACT

Los métodos convencionales de analgesia obstétrica no están exentos de contraindicaciones y riesgos para la madre o el fruto de la gestación, por eso el objetivo de este trabajo es evaluar la estimulación eléctrica transcutánea (TENS) como método no invasivo de analgesia. Materiales y Métodos: Se trata de un estudio prospectivo, descriptivo que toma como universo 18 pacientes primigestantes en fase activa de trabajo de parto a quienes se coloca TENS (Meditronic 7775) con 4 electrodos paralelos paravertebrales con frecuencia de 100 Hertz y amplitud de pulso de 100 milisegundos. Las mismas pacientes sirvieron de grupo de control, al evaluar alternativamente cada hora, el grado de dolor con el TENS prendido y apagado, sin que la paciente lo supiera. Se utilizó la escala alfanumérica de 0-10 para evaluación de intensidad de dolor. Resultados: Once pacientes (61.11 por ciento( refirieron disminución moderada, 3 (16.60 por ciento) disminución leve y una (5.55 por ciento) disminución excelente; aumento del dolor, refirieron 2 pacientes (11.11 por ciento) y no modificación una paciente (5.55 por ciento). 16 pacientes (88.89 por ciento) manifestaron interés de usar TENS en una futura gestación. El apgar de los neonatos no se alteró por el uso de TENS. No se encontró disminución del dolor en los períodos en que el TENS estuvo apagado, ni hubo alteraciones locales en los sitios de aplicación de electrodos. Conclusiones: Consideramos que esta tecnología no invasiva, es eficaz, fácil de usar y no altera el bienestar de la madre o el fruto, por lo cual se recomienda difundir su conocimiento y evaluar series más grandes


Subject(s)
Humans , Female , Pregnancy , Adult , Analgesia, Obstetrical/adverse effects , Analgesia, Obstetrical/methods , Analgesia, Obstetrical
19.
Rev. argent. anestesiol ; 50(2): 78-84, abr.-jun. 1992. tab
Article in Spanish | LILACS | ID: lil-233729

ABSTRACT

Se evaluó la analgesia lograda con N2O/O2 al 50 por ciento, premezclado (Entonox), administrada interminentemente durante el trabajo de parto y período expulsivo. Participaron 75 pacientes ASA I-II que fueron divididos en cuatro grupos. Grupo 1: 19 pacientes, recibieron meperidina 25 mg. endovenosos; grupo 2: 31 pacientes, N2O/O2 al 50 por ciento; grupo 3: meperidina y luego N2O/O2 (16 pacientes) y grupo 4: 10 pacientes que no recibieron analgésicos durante su trabajo de parto. La analgesia lograda con la mezcla N2O/O2 fue significativamente superior al empleo de meperidina. Más del 70 por ciento las pacientes obtuvo analgesia satisfactoria con N2/O2 y sólo un 15 por ciento con meperidina. Se valoró la repercusión de la mezcla gaseosa sobre la madre, el feto y neonato. Todas las pacientes permanecieron conscientes y cooperativas. Tensión arterial, frecuencia cardíaca y dinámica uterina, no se alteraron con la administración de la mezcla. La saturación de oxígeno con la hemoglobina materna fue la esperada en la casi totalidad de las pacientes, excepto en 5 donde la saturación cayó, luego de respirar la mezcla, durante la relajación uterina. El feto, estudiado a través de monitor electrónico, el neonato mediante escala de Apgar y un grupo reducido de ellos además con pH y gases en sangre de arteria umbilical, no se vieron afectados adversamente con la administración de este analgésico a la madre. La mezcla N2O/O2 al 50 por ciento se presenta como la posiblidad de ofrecer a la paciente en trabajo de parto una anlgesia superior, sin afectar adversamente a la madre, feto y neonato.


Subject(s)
Humans , Female , Pregnancy , Analgesia, Obstetrical/adverse effects , Analgesia, Obstetrical/methods , Analgesia, Obstetrical , Fetal Monitoring , Meperidine/administration & dosage , Nitrous Oxide/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL